Gateway deprecated settings

EOL

This documentation is archived and will no longer be updated.

Introduction Copied

This section describes the settings which have been deprecated from the Gateway schema.

Authentication Copied

authentication > allowPaoLogin Copied

This setting has been deprecated as PAO is no longer supported.

authentication > groups Copied

The (optional) groups section contains any number of uniquely named user-group definitions.

Mandatory: No

Default: No groups defined

authentication > users > user > email Copied

Deprecated: Use authentication > users > user > information instead, which allows the inclusion of generic information. Use the value type “Email”.

Mandatory: No

Database Suspend Command Copied

The command Database > Suspend (available on Gateway in the Gateways view in Active Console) where you had to tick/untick the “Suspend database” checkbox to suspend /unsuspend logging of database item values has been deprecated.

You should now use the commands DatabaseLogging > Itemvalues > DiscardandDatabaseLogging > Itemvalues > Log. The old command can still be scheduled through scheduled commands / tasks for backward compatibility.

Database Suspend On Error Setting Copied

This setting has been deprecated and you should now use discardItemValuesOnError setting.

In this setting, you can configure multiple error codes. When any of these error codes are returned from the database, it triggers discarding of database item values and these updates are not be logged to the database (or saved to disk if the database isn’t available).

This setting takes a text input and a wildcard search (pattern) is used to match the error against the error string returned from the database.

For example, the database may throw back error like:

[2003] Can't connect to MySQL server on 'ITRSPC000.ldn.itrs' (110)

Any substring of this error message such as “2003” or “[2003]” or “Can't connect to MySQL server on 'ITRSPC000.ldn.itrs'” will match this error message.

To start logging of database item values again, you need to issue command DatabaseLogging > Itemvalues > Log.

Please refer to Database logging errors for a list of possible error codes returned from different database vendors.

Managed Entities and Managed Entity Groups Copied

Banner variables Copied

Depreciated as of Geneos version 5.0.0

Banner variables allow you to quickly see the value of the most important monitoring metric for a specific managed entity, for example the current CPU load.

Each managed entity can be optionally configured with a single banner variable. The value of this variable is displayed as part of the managed entity icon in Active Console 2, and is updated as the variable changes.

To configure a banner variable, enable the banner setting in the Advanced tab and supply the name of the data-item to display in the banner. This name can be either an absolute name or a relative name which starts from the managed entity being configured.

managedEntities > managedEntity > banner Copied

An optional name specifying the data-item to display as the representative value for this managed entity.

Names can be specified either as an absolute name, or a relative name starting from the managed entity level.

Mandatory: No

Default: None

Scheduled Commands Copied

scheduledCommands > scheduledCommand > recurrence > pattern > hourly Copied

This setting has been deprecated. Please use hours recurrence pattern.

scheduledCommands > scheduledCommand > recurrence > pattern > daily Copied

This setting has been deprecated. Please use days recurrence pattern.

scheduledCommands > scheduledCommand > recurrence > pattern > weekly Copied

This setting has been deprecated. Please use weeks recurrence pattern.

scheduledCommands > scheduledCommand > recurrence > pattern > monthly Copied

This setting has been deprecated. Please use months recurrence pattern.

Self-Announcing Netprobes Copied

Filters Copied

selfAnnouncingProbes > filters Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

Filters are used to control which Self-Announcing Netprobes can connect to the Gateway, based on the managed entity attributes specified in the Netprobe setup. There are three types of conditionals configurable for filters:

Filters are checked in the order they are defined in the setup. The first filter that matches the probe determines whether to allow or deny the connection.

If a probe does not match any filters in the list, the catch-all filter action determines whether the probe is allowed to connect or denied.

Caution

The condition defined by a filter must be true for all managed entities defined on a Self-Announcing Netprobe or the probe will be rejected.

Mandatory: No

Default: None, catch-all filter determines behaviour in this case

selfAnnouncingProbes > catch-allFilter Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

The value of this setting determines whether to allow or deny the connection from a Self-Announcing Netprobe that does not match any of the filters configured in filter .

Mandatory: Yes

Default: ALLOW

selfAnnouncingProbes > filters > filter > name Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

This setting specifies the name of the filter. Several filters can have the same name. There is no requirement at the time being for the name to be unique.

Mandatory: Yes

selfAnnouncingProbes > filters > filter > allow Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

When specified, any probe that matches this filter will be allowed to connect to the gateway.

Mandatory: One of allow or deny must be specified.

selfAnnouncingProbes > filters > filter > deny Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

When specified, any probe that matches this filter will be denied from connecting to the gateway.

Mandatory: One of allow or deny must be specified.

Filter Types Copied

selfAnnouncingProbes > filters > filter > and Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

The and filter combines the results from all sub-filters to form the logical conjunction result.

That is, this filter will only match the probe if all sub-filters match the probe, or if there are no sub-filters.

Mandatory: No

Default: When no sub-filters are configured, the filter will match the probe.

selfAnnouncingProbes > filters > filter > or Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

The or filter combines the results from all sub-filters to form the logical disjunction result.

That is, this filter match the probe if at least one sub-filter matches the probe, or if there are no sub-filters.

Mandatory: No

Default: When no sub-filters are configured, the filter will match the probe.

selfAnnouncingProbes > filters > filter > entityAttributeComparison Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

The entity attribute comparison filter allows you to specify an attribute in the Managed Entity (of the self-announce probe) to perform a comparison against.

As a contrived example, you can use this to filter all probes in London by specifying the name setting as “City” and the value setting as “London”.

Note

This assumes that there are
managed entity attributes called “City” that have been configured correctly.

Mandatory: No

selfAnnouncingProbes > filters > filter > entityAttributeComparison > name Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

The name of the managed entity attribute which will be compared.

If the attribute does not exist on the entity, the filter will behave as if the attribute has an empty string value.

Mandatory: Yes

selfAnnouncingProbes > filters > filter > entityAttributeComparison > comparison Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

Mandatory: Yes

selfAnnouncingProbes > filters > filter > entityAttributeComparison > value Copied

Deprecated. Gateway can accept Self-Announcing Netprobes with multiple managed entities.

The value to compare the managed entity attribute against.

Mandatory: Yes