Windows Netprobe - ERROR: HARDWARE PdhEnumObjectItems() failed with code
Problem Copied
Error encountered: ERROR: HARDWARE PdhEnumObjectItems() failed with code 0xc0000bb8
Sampling status:
Possible cause Copied
This log is associated with errors and problems with the Performance (Perfmon) counters on the Windows server. There is a known bug where the hardware plugin stops working with the error: Cannot access CPU Performance Data. Please check if user privileges are sufficient when adding a specific Perfmon sampler. for version 6.9.0
Possible solution(s) Copied
This bug was fixed in version 7.4.0, upgrading should help resolve the issue.
Other workarounds:
- Disable the Hardware sampler and Perfmon sampler.
- Save the configuration.
- Restart the NetProbe service.
- Re-enable the Hardware sampler and Perfmon sampler. Note: The workaround above restores functionality, but only until the NetProbe is restarted again.