Back to Geneos FAQ

Internal documentation only

This page has been marked as draft.

Hardware - Incorrect 'lastRebootTime' and/or 'uptime' on Hardware plugin

Problem: If the uptime is in XX mins format, the hardware plug-in could not parse the value properly resulting to incorrect lastRebootTime or uptime values.

Action: This was addressed in netprobe version GA4.11.1. You need to upgrade to GA4.11.1 or higher version to resolve this issue.

In the example below, lastRebootTime is incorrect on Hardware plugin dataview.

OS: AIX 6.1 00F8A16A4C00

Netprobe version: GA4.10.2-190318 (any version lower than GA4.11.1)

Command Line output:

-bash-4.2# last reboot
reboot ~ Feb 11 21:54
reboot ~ Sep 23 14:17

-bash-4.2# uptime
10:17PM up 148 days, 22 mins, 2 users, load average: 1.98, 1.81, 1.96

Hardware dataview:

lastRebootTime in Hardware dataview

["Geneos"] ["Geneos > Netprobe"] ["FAQ"]