How to Handle UI Failover in OP5 Master-Peer Setup
Related to: Copied
High availability and UI access in an OP5 cluster with multiple masters.
Problem: Copied
When Master01 is inactive, users accessing the UI via FQDN pointing only to Master01 see all hosts and services reporting 0/0, even though Master02 is active. Current setup treats Master01 as the primary UI access point and Master02 as a peer with additional integrations (Grafana, Kafka).
Possible cause(s): Copied
- FQDN resolves only to Master01.
- OP5 does not support automatic UI failover between masters.
- Secondary master may differ in dashboards, user permissions, and configuration; mirroring the full UI is not supported.
Possible solution(s): Copied
- Designate one master as Primary Master for all configuration changes, API requests, and normal UI access.
- The secondary master can continue running checks and host limited dashboards to monitor continuity.
- Users should not access both masters simultaneously for full UI operations, as this can cause incompatible changes.
- Optional: Set up a simple secondary dashboard on Master02 for basic UI functionality during Primary Master downtime.
- Ensure all peers can run as standalone masters if needed, but accept that full UI mirroring is unsupported.