MinTLSversion parameter not present in Windows netprobe service startup options
Related to Copied
Windows netprobe, Secure communications, SSL/TLS, Installation.
Problem Copied
A user installed a Windows netprobe with minTLSversion set to 1.2 using the /verysilent installation option.
geneos-netprobe-standard-7.3.0.windows-x64.setup.exe /servicename=NetprobeNT-7.3.0-silent01 /netport=8069 /nopassword /secure /ssl-certificate=C:\Users\agalorio\Downloads\geneos-netprobe-standard-7.3.0-windows-x64.setup\np.crt /ssl-certificate-key=C:\Users\agalorio\Downloads\geneos-netprobe-standard-7.3.0-windows-x64.setup\np.key /verysilent /minTLSversion=1.2
However, upon viewing the netprobe service, the minTLSversion parameter is missing from the ‘Path to executable’
Cause Copied
-
**Root Cause:**The minTLSversion parameter is not added to the netprobe service’s startup options. Instead, it is added to the netprobe’s registry keys and values.
Possible solution Copied
- Solution 1: Although the installation works as expected, you may remove the
/verysilentinstallation option to manually select theminTLSversionfrom the installation GUI.